As part of our ongoing process of continuing improvement, Omega Flex has developed an improved version of TracPipe® AP. This is a second-generation product that is an effective but affordable tool in increasing the protection corrugated stainless steel tubing of CSST gas piping systems from the damage caused by nearby, indirect lightning strikes. This version takes the already proven capabilities to an even higher level.
TracPipe AP is a patented CSST innovation based on our existing CSST product, but that is engineered to significantly decrease the potential for lightning induced damage to fuel gas piping systems. TracPipe AP has been designed with a proprietary jacket material in place of the standard yellow jacket. This black jacket has energy dissipating properties that will help protect the TracPipe AP stainless steel pressure liner as well as other fuel gas system components if the pipe becomes energized due to lightning.
The improved version of TracPip AP is designed to withstand significantly higher levels of lightning energy when compared to first generation TracPipe AP and, of course, to conventional TracPipe with the yellow jacket.
TracPipe AP has been shown to be up to 400 times more resistant to the damaging effects of electrical energy than conventional CSST, and is at least 6 times more resistant to that damage than the previous version of TracPipe AP.
No product, including the improved TracPipe AP is immune to the damage caused by a direct lightning strike. Refer to NFPA 780 for lightning protection systems for buildings and building systems.
TracPipe AP Advantages
There are no additional bonding requirements for TracPipe AP imposed by the manufacturer’s installation instructions. With improved properties, TracPipe AP is to be bonded in accordance with current requirements of the National Electrical Code (NFPA 70), and the National Fuel Gas Code (NFPA 54), and with any local requirements that may be in excess of the national codes. This may result in the avoidance of additional bonding costs which are required for conventional CSST.
TracPipe AP is listed by CSA to ANSI LC 1. TracPipe AP meets building code requirements (ASTM E84) with respect to flame spread and smoke density. This permits installation in drop ceilings used as return air plenums, and is UL Listed for 1,2, and 4 hour through penetration firestop systems without removal of the jacket.
TracPipe AP Performance (Testing)
The capability of TracPipe AP to withstand electrical energy has once again been tested by a leading U.S lightning laboratory. The laboratory duplicated typical field damage attributed to lightning for CSST. The electrical energy level in coulombs (the amount of electricity provided by a current of one ampere flowing for one second) that was known to cause damage to our standard CSST was used as a baseline to determine the performance level of TracPipe AP. When tested against our standard CSST, the latest version of TracPipe AP exceeded the performance of the previous generation of TracPipe AP by at least 400%.
For an in-depth look at Technical Solutions, download the TracPipe AP brochure.
Visit TracPipe USA »
Visit TracPipe UK »